Meet N2N at Intersolar 2026 — Munich, 23–25 JuneBooth C4.660FBook a slot
n2n

Quasar Edge · Utility-Scale

Utility-Scale Edge Controller

Grid-code certified. TSO-grade. Quasar Edge is the cabinet-grade controller for utility BESS and hybrid plants — IEC 61850 + IEC 60870-5-104 native, dual-redundant Ethernet, hardened for substation deployment. Deployed up to 95 MW / 95 MWh.

N2N Quasar Edge utility-scale cabinet controller

TSO-grade, grid-code certified

Cabinet-grade hardware designed for utility BESS and hybrid plants. Native protocols on both plant and TSO sides. Closed-loop POI control with capability-envelope awareness.

TEIAS IEC 60870-5-104 native

TEİAŞ-Ready Out of the Box

IEC 60870-5-104 native on both internal and operator sides. ICCP / TASE.2 ready. No extra gateway hardware, no extra license.

P-Q capability envelope control

Closed-Loop POI Control

Active + Reactive power control at the Point of Interconnection. Capability envelope (banana curve) honored. Transformer and cable losses auto-compensated.

PFR / SFR / mFRR grid services

Grid Services Ready

PFR / SFR / mFRR / Synthetic Inertia + LVRT/HVRT envelopes per TEİAŞ and ENTSO-E NC RfG.

Features

Built for the substation

Cabinet-Grade Hardware

SICAM A8000 or N2N RTU. Rittal AX cabinet, IP54+, lockable, tamper-alarmed. Field-proven.

Substation-Grade Protocols

IEC 61850 (GOOSE + MMS), IEC 60870-5-104, Modbus, CAN. Plant-side and TSO-side both native.

Redundant Connectivity

Dual-redundant Ethernet + 4G/LTE backup. DEHN + Phoenix Contact + Schneider surge protection. DC UPS with 30-min graceful shutdown.

Defense-in-Depth Cybersecurity

mTLS, IPsec, secure boot, signed firmware, RBAC, audit logging. NIS2 + EPDK siber compliant.

Architecture

Plant to TSO,
both sides native

Quasar Edge is the cabinet-grade controller that lives in your plant's substation. Plant-side, it speaks IEC 61850 GOOSE + MMS to inverters and BMS containers. Operator-side, it speaks IEC 60870-5-104 over IPsec VPN to the TSO SCADA. Store & Forward telemetry buffer means link drops do not lose data — when connectivity restores, every sample is delivered in order.

IEC 61850 + 60870-5-104 + Modbus + CAN — plant and TSO sides both native
Dual-redundant Ethernet + 4G/LTE failover + DC UPS
Store & Forward telemetry buffer for link interruptions
Capability envelope-aware closed-loop POI control
Quasar Edge connectivity diagram showing utility plant, substation cabinet and TSO SCADA

Capabilities

Beyond a gateway

A complete utility-scale BESS controller. P-Q closed-loop, imbalance management, hybrid coordination and augmentation planning — all proven up to 95 MW / 95 MWh.

Active + Reactive Power Control

Setpoint, ramp rate, curtailment, gradient. Q-V droop, cos φ, STATCOM-like operation. Typical ramp: 5-10 MW/min per TEİAŞ directive.

Imbalance Management

AI forecast (Solcast + 90-day learning) closes the gap between forecast and actual through battery dispatch. Target: 99.4% forecast adherence, zero imbalance penalty.

Hybrid Coordination

PV + BESS unified at the POI. Peak PV flows into the battery instead of being curtailed — typically 12-15 MWh/day saved on a 95 MW plant.

Asset Performance + Augmentation Planning

Cell-level SoH heatmap. AI degradation models warn 18 months before SLA breach so augmentation CAPEX is budgeted on time.

Specifications

Technical details

Engineered for the substation. Every component is selected to survive 25 years of utility-scale field service.

ProcessorARM-based Linux
Operating Temp-40°C to +75°C
ProtocolsModbus, CANbus, IEC 61850, OCPP
ConnectivityEthernet, Wi-Fi, 4G/5G
SecurityEnd-to-end encryption, secure boot
I/ORS-485, RS-232, Digital I/O, Analog
CertificationsCE, FCC, IEC 62443
Power9-36V DC, < 10W consumption

Use Cases

One controller, every utility scenario

Standalone Utility BESS

Frequency regulation, energy arbitrage, capacity market participation. Deployed up to 95 MW / 95 MWh.

Hybrid PV + BESS Plant

Single POI controller. Curtailment-free dispatch. Forecast-aligned export keeps imbalance penalties at zero.

TSO Yan Hizmetler Pazarı

PFR, SFR, mFRR pre-qualification support. European PICASSO / MARI prequalification on the roadmap.

Multi-Plant Fleet Operator

Each plant deploys its own Quasar Edge; the Quasar cloud orchestrates the fleet from a single panel.

Get to know
Quasar Edge

Evaluating Quasar Edge for a utility BESS or hybrid plant tender? Share your project envelope — grid code, POI capacity, BMS vendor, TSO requirements — and we will come back with a compliance matrix, deployment timeline and reference plant data.

Grid code compliance matrix
Reference plant data (under NDA)
Deployment timeline and cabinet BoM
TSO integration walkthrough