n2n

Pulsar Edge · Commercial & Industrial · C&I

Industrial Edge Gateway

EMS, SCADA and RTU in a single box. Pulsar Edge orchestrates your factory, mall, hotel or hybrid plant — PV, BESS, grid, loads and gensets — with real-time response, vendor-agnostic protocol support and retrofit-ready deployment on top of any existing system. Built for the C&I segment.

N2N Pulsar Edge ME-100 industrial edge gateway

EMS + SCADA + RTU, one box

Collapse the stack. Pulsar Edge runs deterministic Soft-PLC safety control alongside AI-driven optimization on industrial hardware — no separate SCADA license, no rip-and-replace.

Multi-asset orchestration HMI

EMS + SCADA + RTU — One Box

No Wonderware, no WinCC, no separate RTU layer. Pulsar Edge collapses the stack into a single fanless IPC.

Retrofit on existing plant

Retrofit-Ready

Drops on top of existing solar plants without touching the SmartLogger, inverter strings or the EPC's original SCADA. Vendor-agnostic upper-level EMS.

Market revenue arbitrage engine

Market Revenue Engine

Native EPİAŞ, EPEX SPOT and ENTSO-E connectors. Your battery turns from a cost line into a trading instrument.

Features

Built for the field

Industrial IPC

Advantech UNO-2372G V2, fanless, -20°C to +60°C, IP66. UPS-backed 30-min graceful shutdown.

Multi-Protocol Native

Modbus TCP/RTU, CAN, EtherCAT, IEC 61850, RS-485. ~50 devices per unit.

Secure Remote Management

4G/LTE with IPsec VPN. Docker-based OTA updates with rollback. Remote diagnostics built-in.

Vendor-Agnostic Library

Huawei, SMA, Sungrow, ABB, Fronius, GoodWe, Solis, SolarEdge inverters + Svolt, Huawei LUNA, Sineneg, DYE BMS. Plug-and-play.

Architecture

Field to cloud,
seamlessly retrofitted

Pulsar Edge sits between your facility's PV, BESS, grid meter, loads and generators — and the N2N HuBBle. It runs deterministic Soft-PLC safety control alongside AI-driven optimization, all locally on industrial-grade hardware. Vendor-agnostic by design: it reads existing inverter loggers (Meteocontrol, Huawei SmartLogger, Solis Logger) and layers EMS + SCADA on top.

Modbus, CAN, EtherCAT, IEC 61850 + universal logger integration
4G/LTE with IPsec VPN + Ethernet redundancy
Local Soft-PLC + AI optimization in two-layer architecture
Retrofit on existing plants — no rip-and-replace
Pulsar Edge connectivity diagram showing C&I site assets, edge gateway and N2N HuBBle

Capabilities

Beyond a gateway

A fully autonomous C&I edge controller. Peak shaving, market arbitrage, EPDK 14311 compliance and predictive maintenance, all running locally.

Peak Shaving & Load Shifting

AI re-optimizes every 15 minutes. Typical factory savings: €2-8K/month in demand charges.

Market Arbitrage (EPİAŞ / EPEX / ENTSO-E)

Day-ahead and intraday position auto-bidding. The battery becomes a revenue asset, not just a cost line.

EPDK 14311 Native

Hourly netting engine built-in. Reports auto-generated. Ready for the 1 May 2026 deadline.

Predictive Maintenance + APM

1 Hz telemetry from 50+ points, 90-day AI anomaly learning, OEM ticket integration for B2B2C revenue.

Specifications

Technical details

Purpose-built for energy infrastructure. Every component is selected for reliability in demanding field conditions.

ProcessorARM-based Linux
Operating Temp-40°C to +75°C
ProtocolsModbus, CANbus, IEC 61850, OCPP
ConnectivityEthernet, Wi-Fi, 4G/5G
SecurityEnd-to-end encryption, secure boot
I/ORS-485, RS-232, Digital I/O, Analog
CertificationsCE, FCC, IEC 62443
Power9-36V DC, < 10W consumption

Use Cases

One controller, every C&I scenario

Factory & Industrial

Peak shaving reduces demand charges. Backup-ready protects critical production lines from outages.

Mall / Office / AVM

Load shifting moves consumption to off-peak. HVAC and lighting orchestrated against tariff.

Hotel / Hospitality

Microgrid mode keeps guests served during outages. Solar + battery optimized for round-the-clock occupancy.

Hybrid Plant (PV + BESS)

Curtailment-free POI coordination. Market revenue from EPİAŞ + EPDK 14311 compliance built-in.

Software

This device is operated in N2N HuBBle

Once commissioning is done the site runs from N2N HuBBle: the same interface on web and mobile, role-based access and two-factor authentication. If the connection drops, the device keeps running its own schedule.

SCADA and live monitoring

Single-line diagram, live telemetry and energy flow.

Control and configuration

Hourly schedules, setpoints, rule sets and device profiles.

Maintenance and alarms

Tiered alarms, asset health and service history.

Reporting

Build and export your own reports; scheduled ones run automatically.

Get to know
Pulsar Edge

Looking to deploy Pulsar Edge on your facility or hybrid plant? Send us your site profile — we will come back with a deployment proposal, protocol compatibility check and a savings projection based on your tariff and load curve.

Personalized site walkthrough
Retrofit deployment planning
Protocol compatibility check
Tariff-based savings projection